Tuesday, 16 March 2021

ventor fillin w water

ok so i checked all the usual suspects... venting good slope not valleys, furnace sloping to the front right (where collector box drain is) all good. took apart entire drain from collector to trap and out n no blockages. take off ventor n dump up about a cup of water put it back on and it fills up w water again. first time was with in 5 min another time it took 30. another time it last over night. my only other thought which i’m gonna try tomorrow is gas pressure. maybe it’s to low n where getting complete combustion so too much moisture is created in the secondary heat exchanger and water is being sucked into the ventor through there? never seen it, but i think in theory it’s possible no? it’s a goodman gmec 96. thoughts?


source https://hvac-talk.com/vbb/threads/2227474-ventor-fillin-w-water?goto=newpost